Imperx BOBCAT User Manual page 161

Ntelligent, high-resolution, field upgradeable, programmable, 8/10/12/14 bit digital cameras
Table of Contents

Advertisement

4.3.4.6 Current Maximum Exposure
This register returns the current camera maximum exposure time in us. The
maximum camera exposure is a dynamic parameter and changes based on the
camera mode of operation.
Address
Data (23:0)
Data (31:24)
4.3.4.7 Current Camera Exposure
This register returns the current camera exposure time in us.
Address
Data (23:0)
Data (31:24)
4.3.4.8 Current Frame Time
This register returns the current camera frame time in us.
Address
Data (23:0)
Data (31:24)
4.3.4.9 Current Image Size
This register returns the current image frame size in pixels. The image size is
a dynamic parameter and changes based on the camera mode of operation.
Address
Data (15:0)
Data (31:16)
4.3.4.10
This register returns the current analog gain and the current average image
luminance during normal, AGC and Tap Balance operation.
The Current Analog Gain (register bits D11:D0) displays:
-
-
-
Address
Data (11:0)
Data (23:12)
Data (24)
Imperx, Inc.
6421 Congress Ave.
Boca Raton, FL 33487
+1 (561) 989-0006
:
:
:
:
:
:
:
:
:
:
:
:
Current Gain & Luminance Status
The current slider gain for tap 1 during normal operation.
The calculated AGC gain for tap1 when AGC/AEC is enabled.
The calculated analog gain for tap 2 when tab balancing is enabled.
:
:
:
:
161 of 265
BOBCAT Hardware User's Manual
0x6090
<Current Maximum Camera Exposure>
N/A
0x609C
<Current Exposure Time>
N/A
0x60A0
<Current Frame Time>
N/A
0x60B0
<Current Horizontal Size>
<Current Vertical Size>
0x60B4
<Current Analog Gain>
<Current Average Luminance>
<Analog Gain Minimum Limit Reached>
Rev. 2.0.2
11/20/2012