Function List; Basic Function Parameter List - Mitsubishi Electric FR-S500 Series Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR-S500 Series:
Table of Contents

Advertisement

Basic function parameter list

6.

FUNCTION LIST

6.1 Basic function parameter list
Param
Name
eter
0
Torque boost
Maximum
1
frequency
Minimum
2
frequency
3
Base frequency
Multi-speed set-
4
ting (high speed)
Multi-speed set-
5
ting (middle speed)
Multi-speed set-
6
ting (low speed)
7
Acceleration time
8
Deceleration time
Electronic
9
thermal O/L relay
Extended function
30
display selection
Operation mode
79
selection
* The factory setting varies with the inverter capacity: 5% for FR-S540E-1.5K and 2.2K, 4% for
FR-S540E-3.7K.
REMARKS
• Setting "1" in Pr. 30 "extended function display selection" makes the extended function
parameters valid. (Refer to page 48.)
• The decimal places of a value of 100 or more (3 digits or more) cannot be set to be displayed.
Setting
Indication
Range
0 to 15%
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 999s
0 to 999s
0 to 50A
0, 1
0 to 4, 7, 8
44
Minimum
Factory
Setting
Setting
Increments
0.1%
6%/5%/4% *
0.1Hz
60Hz
0.1Hz
0Hz
0.1Hz
60Hz
0.1Hz
60Hz
0.1Hz
30Hz
0.1Hz
10Hz
0.1s
5s
0.1s
5s
Inverter rated
0.1A
current
1
1
Customer
Setting
0
0

Hide quick links: