2.

INSTALLATION METHOD

2.1 Installation of the inverter

Enclosure surface mounting
Leave enough clearances
and provide cooling measures.
Install the inverter under the following conditions.
Ambient temperature
and humidity
Temperature: -10°C to 50°C
Humidity: 90%RH maximum
Inverter
5cm
(1.97inches)
5cm
Measurement position
(1.97inches)
Inverter consists of precision mechanical and electronic parts. Never install or
handle it in any of the following conditions as doing so could cause an operation
fault or failure.
Direct sunlight
Vertical mounting
(when mounted
inside enclosure)
Fix the front
cover and wiring
cover after
removing them.
Clearances (front)
1cm
(0.39inch)
or more
10cm
(14°F to 122°F)
(3.94inches)
or more
These clearances are also
Measurement
position
necessary for changing the
cooling fan. (
5cm
more is provided with a
(1.97inches)
cooling fan.
Vibration
(5.9m/s
or more)
2
Transportation
by holding front
cover or dial
Encasing multiple inverters
When containing two or more
inverters, install them in parallel
and provide cooling measures.
10cm
(3.94inches)
or more
1cm
(0.39inch)
or more
The 1.5K or
)
High temperature,
Horizontal placement
high humidity
Oil mist, flammable
Mounting to
gas, corrosive gas,
fluff, dust, etc.
combustible material
5
Installation of the inverter
Vertical
Clearances (side)
5cm
Inverter
(1.97inches)
or more
2

Hide quick links: