Warnings; Electrical Component Installation - Laguna Bay Spas Spa Owner's Manual

Energy saver spa equipment
Table of Contents

Advertisement

LAGUNA BAY SPAS RECOMMENDS THAT YOUR SPA BE INSTALLED BY A
To ensure the spa functions properly and to ensure your warranty is not
compromised by improper installation, you must have a licensed electrician
install all electrical components. Connect only to a grounded source.
If your spa model is equipped with a cord, do not bury the cord. A buried cord
may result in death or serious injury due to electrocution if direct burial-type
cable is not used, or if improper digging occurs.
Install at least five feet (1.5m ) from all metal surfaces. If this is not possible, a
ground terminal (pressure wire connector) is provided on the control box inside
the unit to permit connection with solid copper bonding conductor between this
point and any metal equipment, metal water pipe, metal enclosures of electrical
equipment, or conduit within five feet (1.5m) and within sight of the spa.
Do not permit any electrical appliances, such as lights, telephones, radios or
televisions within five feet (1.5m) of the spa unless they were built in by the
manufacturer. Failure to maintain a safe distance may result in death or serious
injury from electrocution if the appliance should fall into the spa.
Your spa requires a Ground Fault Circuit Interrupter for user and
equipment protection in compliance with section 680-42 of the
National Electrical Code, ANSI/NFPA 70-1993. To ensure proper
operation of the important safety device, test according to the
following instructions with regard to your electrical configuration.
Plug the spa directly into the power source. Do not use an extension cord or
surge protector. The GFCI is located at the end of the power cord.
Before each use, with the unit operating, push the "test" button.
The unit should stop operating and the GFCI power indicator will
go out. Wait 30 seconds and then reset the GFCI by pushing the
"RESET" button. The GFCI power indicator will turn on, restoring
the power to the spa. If the interrupter does not perform in this
IMPORTANT INFORMATION
ABOUT SPA SAFETY
AVOIDING THE RISK OF ELECTROCUTION
LICENSED ELECTRICIAN.
CORD-CONNECTED 115 VOLT, 20 AMP
WARNING
5