220V Spa Installation; Gfci Wiring Diagram - Laguna Bay Spas Spa Owner's Manual

Energy saver spa equipment
Table of Contents

Advertisement

Electrical Information
If your electrician has questions about the wiring
instructions,
to starting installation at (877) 722-4097. Factory trained technical
service specialists are available to answer questions during their normal business
hours Monday through Friday from 8:30 am to 5 PM est.
Correct wiring of the electrical service box,
is required. Spas installed for 220v operation require a 4-wire, 50 amp or 60 amp
(depending on the spa model), 220 volt subfeed in non metallic pipe to the spa
equipment compartment.
Main Service
Panel
16
220V Installation
please call Laguna Bay Spas Technical Assistance prior
US and Canadian GFCI Wiring Diagram
GFCI box and pack terminal block
Spa GFCI Panel
must be accessible but
at least 5 feet (1.5m)
from the spa.
The black and red wires
electrical box must be connected
to the input of the GFCI.
The white wire
electrical box must be connected
to the neutral bus.
The green or copper wire
be connected to the ground lug of
the GFCI.
The black, red and white
wires going to the spa must be
connected directly to the output
of the GFCI.
The neutral to the GFCI
connected to the neutral bus.
The green or copper wire
to the spa must be connected to
the ground lug.
from the
from the
must
must be
going