Electrical Information

All electrical connections must be performed by a
qualified licensed electrician in accordance with the
National Electric Code (NEC) and with state and local
electrical codes in effect at the time of the installation.
Connecting the spa to an improperly wired circuit will eliminate many of the
spa's built in safety features which may result in fire, electrocution, or other risk
of injury. Damages to the spa which are the result of improper wiring are not
covered under the manufacturer's warranty and will terminate all listings from
independent listing agencies. The electrical diagrams contained in this manual
are included as a guideline for the licensed electrician installing the electrical
connections and may vary by model. Please refer to the diagram in the spa
control box.. All wiring connections must be watertight.
Never turn power on to the spa when it is not filled with
water !
automatically activates critical components within the spa, such as the
controls and the heating. If power is supplied to the components prior to the
spa being filled, the components will be damaged. Damage that occurs to the
components because power was supplied before the spa was filled with water is
not covered by the manufacturer's warranty.
Prior to performing any service to your Laguna Bay Spa,
turn OFF all primary electrical equipment at the main
circuit breaker or disconnect panel.
Bay Spa must be permanently connected (hard wired) to the power supply.
No plug in connections, extension cords or surge protectors are to be used
in conjunction with the operation of your new spa. Power supplied to your
Laguna Bay Spa must be a dedicated circuit with no other appliances, lighting,
or any other electronic components powered by this circuit.
The electrical supply for this product must be housed in
a weatherproof service box and include a suitably rated
switch or Ground Fault Circuit Interrupter
main service entrance and the spa to open all ungrounded supply conductors
in compliance with Section 422-20 of the National Electrical Code/USA, ANSI/
14
AVOID THE RISK OF ELECTROCUTION.
DO NOT Connect power to the empty spa. Power to the spa
Your 220V Laguna
between the