Electrical Information
To allow the 220V GFCI to function properly,
wire from the spa to the Neutral terminal on the GFCI breaker, not the Neutral
bus in the GFCI breaker box. An improperly connected Neutral causes the
GFCI breaker to trip.
A green colored terminal is provided in the control box.
electrical shock, connect this terminal or connector to the grounding terminal of
your electrical service or supply panel with a continuous green insulated copper
wire.
A second pressure wire connector is provided
for bonding to local ground points. To reduce the risk of electrical shock, this
connector should be bonded with copper wire to any reinforced concrete, metal
water pipes, or any metal within 5 feet (1.5m) of the spa. International customers
should contact their Laguna Bay Spas dealer for Electrical Wiring Requirements.
Refer to supplied wiring diagrams inside the control box for model specific
diagrams
and call technical support associate for assistance prior to wiring the
controls for assistance if necessary. Factory trained technical service specialists
are available to answer questions by calling (877) 722-4097 during their normal
business hours Monday through Friday from 8:30 am to 5 PM est.
Do not replace the exterior cabinet panel
Spa has been filled with water and you are sure it is operating properly.
Be sure to hand tighten the unions in the plumbing lines and ensure the
slice valves are locked in the up position before filling the spa.
Wiring the Spa Controls
From GFCI
Ground Terminal Block
(Attached to outside of
Spa Control Box)
connect the white Neutral
Spa Controls
Black
(HOT)
White
(Neutral)
Red
(Hot)
Green
(Ground)
on the surface of the control box
until your new Laguna Bay
To reduce the risk of
17