5- Connections

L
MINOR 11
L
MINOR 11
The reference number of the underfloor sensor to
use is 6300037.
Load
Pilot
Underfloor
Wire
sensor
10A - 230V
L
N
6 7
Pilot wire from
programmer
Maximum load 2.300 W
Max. power: 2,300 W, otherwise relay
Load
Pilot
Underfloor
Wire
sensor
10A - 230V
L
N
6 7
Pilot wire from
programmer
load
The relay capacity depends on
the power to be switched
- 8 -

6- Switching on the unit for the first time

When the MINOR 11 is first switched on, it starts up
the "gradual heating" mode designed for new
underfloor heating systems for which a gradual
heating is recommended (over a period of 20 days).
In this mode, the heating percentage is limited to 8%
on the 1
st
day, 12% the 2
20
th
day.
The display shown the number of
remaining days and
The
symbol flashes.
- The program can be stopped at
any moment by pressing
- pressing the button
program P1.
After the 20-day period, MINOR 11 exits the gradual
heating mode and returns to the Off mode.
The heating can always be started again in gradual
heating mode. (see Installer commissioning).
- The percentage shown above is calculated in
relation to the regulation time base,
- The gradual heating mode depends on the
set-point temperature.
nd
day... up to 100% on the
.
.
displays the current
- 9 -