Zone thermostat for underfloor heating
Hide thumbs Also See for DELTA 8000 TA BUS:

Advertisement

DELTA 8000 TA BUS
Zone thermostat for Underfloor heating
EN
Installation instructions

Advertisement

loading

Summary of Contents for DELTA DORE DELTA 8000 TA BUS

  • Page 1 DELTA 8000 TA BUS Zone thermostat for Underfloor heating Installation instructions...
  • Page 2: Table Of Contents

    TECHNICAL CHARACTERISTICS CONTENTS • Power supply by the bus, 24V • Bus Input/output 2 wires 1/ Location/Mounting • Class III insulation • Surface-mounted or on flush-mounting box 2/ Association of the thermostat with the technical unit. • Dimensions: 81 x 88 x 21 mm •...
  • Page 3: 1/ Location/Mounting

    1/ LOCATION/MOUNTING Since the temperature measurement sensor is inside the unit, you must install the thermostat flush-mounting box: ~1,50 m - on an accessible wall at a height of 1.50 m - away from heat sources (fireplaces, sunlight) and draughts (windows, doors) IMPORTANT: Do not install the thermostat on Mini 20 cm a wall in contact with the outdoors or with an...
  • Page 4: 2/ Association Of The Thermostat With The Technical Unit

    2/ ASSOCIATION OF THE THERMOSTAT WITH THE TECHNICAL UNIT. ❶ Press and hold the 1st and the 4th button Output 1 to 16 depending on for 3 seconds. Release. number the system. ❷ The screen displays CF20. Underfloor heating Press OK then press + and - to select the (by default) Transmitter output with which the room thermostat will be...
  • Page 5: 3/ Configuring The Room Thermostat

    3/ CONFIGURING THE ROOM THERMOSTAT ❶ From the OFF mode. HEAT/ Press and hold the 2nd COOL Temperature On/Off button from the left for mode management management manage- 5 seconds. ment Release. On the Master On all ❷ Tap the OK button. controlled On all zones thermostat...
  • Page 6 3/ CONFIGURING THE ROOM THERMOSTAT Correction of the measured +/- 5°C in 0.1°C increments (0°C by default) temperature Setting display (default selection) Temperature displayed in normal mode Display of the measured temperature. No ban (default selection) Ban on the Cool regulation on the thermal zones of the Room Temperature (if SW2 = ON) No (default selection)
  • Page 7 3/ CONFIGURING THE ROOM THERMOSTAT 0 Not activated Activation of the window/door magnetic contact function (the room thermostat switches to Frost Protection mode if the window/door magnetic 1 Activated (default selection) contact is activated). 'Presence detection' function 0 Not activated (the thermostat lowers its setting in the 1 Activated (default selection) event that no presence is detected).
  • Page 8: 4/ Initialisation

    4/ INITIALISATION 4.1 DELETING ALL THE ASSOCIATION BUS WITH THE TECHNICAL UNIT ❶ From the OFF mode. Press and hold the 2nd button from the left for 5 seconds. Release. ❷ Press and hold the 2nd button from the left again for 3 seconds.
  • Page 9: Deleting The Association Of The Thermostat With The Technical Unit

    4/ INITIALISATION 4.2 DELETING THE ASSOCIATION OF THE 4.3 INITIALISING THE ROOM THERMOSTAT THERMOSTAT WITH THE TECHNICAL UNIT SETTINGS Press OK to open the setting, then press + and - to This menu restores the system select «= --». to factory settings. Confirm with OK.