2- Presentation

Relay status
Set-point
temperature or
temperature
measured per
MINOR 11
Selection of
the operating mode
or configuration
(installer)
Adjustment buttons
15 mm 33 mm
Part fitting into the
flush-mounted box
Current mode
Heating
demand
mode
Auto
Off
Comfort
Economy
Frost
Protection
80 mm
- 4 -
• Suitable for underfloor heating or radiant ceiling
heating
• Permanent regulation (proportional integral)
• Simple control system (pilot wire principle)
• Up to 6 operating modes (GIFAM standard)
2.1 The pilot wire principale (CALYBOX standard)
The pilot wire principle enables the required
operating mode to be selected from a programmer
(CALYBOX range, Driver range, etc.).
The MINOR 11 thermostat thus controls the
corresponding temperature.
Order sent by
Corresponding temperature
the programmer
controlled by the thermostat
Comfort
Comfort setting (5°C to +30°C)
Comfort- 1°C
Comfort - 1°C setting
Comfort- 2°C
Comfort - 2°C setting
Economy
Economy setting (5°C to +30°C)
Frost protection Frost protection can
Frost Protection
be set from 5°C to 15°C (7°C by default)
Off
Heating switched off