Welding Functions - Kemppi 350 Operating Manual

Fastmig pulse
Table of Contents

Advertisement

wiserOOt / wisethin
WFSpeed
WFS-Max
WFS-Min
BaseCurrent
BaseCurrentMax
BaseCurrentMin
FormingPulse
FormingPulseMax
FormingPulseMin
StartTime
StartVoltage
* Different welding curves may further restrict the value range further.
MMa PrOCesses
EN
Current
CurrentMax
CurrentMin
ArcForce

4.3.2 welding functions

Other PrOCesses
2T/4T
HotStart
HotStartLevel
Hot 2T Time
CraterFill
CraterStart
CraterFillEnd
12
0.7 – 14 m/min *
-50 ... +50
-50 ... +50
1% steps
-50 ... +50
1% steps
-30 ... +30
-30 ... +30
1% steps
-30 ... +30
1% steps
-9 ... +9
Factory setting is 0
-30 ... +30
Factory setting is 0
14 – 350A/450A
14 – 350A/450A
14 – 350A/450A
-9 ... +9
Factory setting is 0
(In Edit Channel menu 3/6)
2T, 4T, MATCHLOG
Factory setting is USER =>
or USER
USER can freely choose the
switching logic
ON, OFF or USER
Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
-50 ... +100 %
1 % steps. Factory setting 40%
0 – 9.9 s
0.1 s steps. Factory setting 1.2 s
ON, OFF, USER
Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
10 – 250%
Factory setting is 100%
10 – 250 %, not
1 % steps. Factory setting 30% Set the level of the curve where the crater
higher than start
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the base current of the curve – the arc length –
within certain limits.
Set the limit for maximum "arc length"
Set the limit for minimum "arc length"
Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
Set the limit for maximum forming pulse current
Set the limit for minimum forming pulse current
Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.
Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
Welding current
Set the limit for maximum current value
Set the limit for minimum current value
Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Set switching logic
Set the level of the curve where the crater
filling will start
filling will end.