Getting Started - Kemppi 350 Operating Manual

Fastmig pulse
Table of Contents

Advertisement

Fe
Fe
Fe
Ss
Ss
Ss
Ss
Ss
4.4

getting started

step by step for the first time user
First select your language
The default menu language is English. In the following steps you will be able to select
NOTE!
alternative languages
1.
Connect mains power and switch on power source. If this is the initial system activation
you may need to press and hold the large orange ON/OFF button on the ARC WIZARD
P65 panel. Top left - Long Press (Approximately 5 seconds).
2.
Now press button marked 'MENU' to display MAIN MENU listing. There are 7 x items in this
MAIN MENU list. As you select each item in the list, the reference number (Bottom
middle display) will change e.g. 2/7 or 5/7 etc, showing which menu item you have
selected. (You can cycle from first to last or last to first in a loop in all menu lists, if you
wish). A black arrow marks your menu item selected.
3.
MENU items are selected via the UP-DOWN buttons marked with orange arrows. These
EN
buttons are situated underneath the encoder knob to the right of the panel. Move the
'black arrow cursor' up and down the menu lists. Press down arrow button selecting item
5/7 marked LANGUAGE. Press soft key button underneath the word SELECT.
4.
Make your language choice as detailed above, and then press the SELECT/SAVE button (right-
hand button next to MENU button). Your language choice is now confirmed and will
remain selected unless you change it later.
new channel job number
FastMig Pulse is designed for production jobs as well as varied specialist operation. Main
welding set-up is made through the ARC WIZARD P65 MENU and recorded to a 'Channel (Job)
Number' of your choice.
When you want to weld you simply select the corresponding channel (Job) number on the
wire feed panel PF65 and weld. Only regular needed controls are present on the wire feed unit
panel PF65, making welding easy and convenient.
If the machine is new and no welding has been completed before, follow these steps.
NOTE!
A. Switch on power source (May require long press of panel ON/OFF button – 5 sec).
1.
Press and select NEW button.
2.
Create New Channel – Press SELECT button.
3.
Choose weld process and press SELECT button.
B. Then follow the steps from item 4 in the list below.
editing an existing channel (job) number
1.
Press button marked 'MENU' to show MAIN MENU listing.
2.
SELECT 'Edit Channel' – Press SELECT button
3.
SELECT 'Select Weld Curve' - Press SELECT button
4.
Choose and SELECT Process. MIG/1-MIG/Pulse MIG/Double Pulse MIG/ or Curve Number List -
Press SELECT button
5.
Choose and SELECT material group – Press SELECT button
6.
Choose and SELECT material grade – Press SELECT button
7.
Choose and SELECT filler wire diameter – Press SELECT button
18
F22
X
X
F23
X
X
F24
X
X
S01
X
S02
X
X
S12
X
S13
X
S14
X
0.9
Fe
1
Fe
1.2
Fe
0.8
Ss-316/308
0.9
Ss-316/308
0.9
Ss-316/308
1
Ss-316/308
1.2
Ss-316/308
CO2
CO2
CO2
Ar+2%CO2
Ar+2%CO2
Ar+He+CO2
Ar+He+CO2
Ar+He+CO2

Hide quick links: