2.6

Controlling welding functions

With FitWeld 300 you can easily control welding parameters, change
the welding polarity and gun operating mode.
The control panel provides two adjustment knobs. You can set the desired welding voltage
and wire feed speed before or during welding, so easily tuning the desired arc performance to
the weld.

2.6.1 Control panel functions

10
9
8
7
With the left-hand control knob, set the value for filler wire feed speed. The maximum value is
18 meters per minute.
EN
With the right-hand control knob, set the welding voltage. Adjustment range is from 11V to
32V.
The leds on the front panel indicate the following (from top to bottom):
• Machine is turned on
• Machine is overheated
• Error in shielding gas flow

2.6.2 Controls inside the machine

3.
1.
Welding gun operation mode switch.
2.
Shielding gas adjustment screw.
3.
Cable connections for reversing polarity.
10
FitWeld 300
FitWeld
1
10
9
2
3
8
4
7
U
6 5
6 5