AMX Modero ViewPoint MVP-8400i Operation/Reference Manual page 78

8.4" modero viewpoint touch panel with intercom
Hide thumbs Also See for Modero ViewPoint MVP-8400i:
Table of Contents

Advertisement

Setup Pages
System Settings Page Elements
Master Connection (Cont.):
Mode
System Number
Master IP/URL
Master Port Number
Username/Password
Refer to the Step 3: Choose a Master Connection Mode section on page 27 for more detailed information
on using the System Settings page.
64
Cycles between the connection modes: URL, Listen, and Auto.
(Ethernet Only - disabled when USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master. The System Number field is read-only - the
panel obtains this information from the Master.
• Listen - In this mode, add the panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero
touch panel to "listen" for the Master's communication signals. The System
Number and Master IP/URL fields are read-only.
• Auto - In this mode, enter the System Number and a username/password (if
applicable). Use this mode when both the panel and the NetLinx Master are
on the same Subnet, and the Master has its UDP feature enabled. The
Master IP/URL field is read-only.
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Allows you to enter the port number used with the NetLinx Master.
• Default = 1319
(ETHERNET Only - disabled when USB is selected)
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master. This
profile should have the pre-defined level of access/configuration rights.
MVP-8400i 8.4" Modero® ViewPoint® Touch Panel with Intercom