5. Toggle the Encryption button (FIG. 22) until it reads either: 64 or 128 for Bit Key Size. 
The 64/128 selection reflects the bit-level of encryption security. This WEP encryption level must
match the encryption level being used on the WAP.
WEP will not work unless the same Default Key is set on both the panel and the
Wireless Access Point.
For example: if you have your Wireless Access Point set to default key 4 (which
was 01:02:03:04:05), you must set the panel's key 4 to 01:02:03:04:05.
6. Toggle the Default Key field until the you've chosen a WEP Key value (from 1- 4) that matches
what you'll be using on your target WAP200G. This value MUST MATCH on both devices.


FIG. 23
WEP Key # Keyboard
7. Write down this Current Key string value for later entry into your WAP's WEP Key field (typically
entered without colons) and into other communicating panel's Current Key field (FIG. 23).
8. If you are entering a Current Key generated either by your target WAP or another Modero
panel, within the WEP Keys section, touch the Key # button to launch the WEP Key # keyboard
(FIG. 23), enter the characters and press Done when finished.

MVP-8400i 8.4" Modero® ViewPoint® Touch Panel with Intercom
The card should be given the SSID used by the target WAP. If this field is left blank, the unit
will attempt to connect to the first available WAP. By default, all WAP200Gs use AMX as
their assigned SSID value.
One of the most common problems associated with connection to a WAP arise because the
SSID was not entered properly. You must maintain the same case when entering this
information. ABC is not the same as Abc.
The alpha-numeric string is by default AMX but can later be changed to any 32-character
entry. This string must be duplicated within the Network Name (SSID) field on the WAP.
As an example, if you use TECHPUBS as your SSID, you must match this word and the
case within both the Network Name (SSID) field on the touch panel's Network Name SSID
field and on the WAP's Basic Wireless Configuration page.
These WEP Key identifier values must match for both devices.
This series of hex digits (26 hex digits for a 128-bit encryption key) should be entered as
the Current Key into both the WAP and onto other communicating Modero panels by
using the WEP Key dialog (FIG. 23).
This Key value corresponds to the Default WEP Key number used on the Wireless Access
Point and selected in the Default Key field described in the previous step.