Press the [+] key again until t4 appears and, for exam-
ple, 18 (18°C), the current outside temperature;
Press [+] key again until fl appears and e.g. ^0
(6uA), the present ionisation current;
Press [+] key again until ñf appears and e.g. 30
(3000 rpm), the present fan speed;
Press [+] key again and the read-out cycle will start again
with t1, etc.;
Press 'Reset'- key to return to the display with the cur
rent operating status.
3.3

Changing settings

The user can change the following settings:
p1 Maximum flow temperature (= water temperature that
leaves the boiler) [°C], adjustable between 20 and 85°C
(factory setting = 75°C)
p2 Maximum domestic hot water temperature [°C], adjust-
able between 40 and 65°C (factory setting = 55°C)
p3 Boiler regulation; central heating and domestic hot water
mode adjustable at four levels:
0 = central heating OFF and domestic hot water OFF
1 = central heating ON and domestic hot water ON
(= factory setting)
2 = central heating ON and domestic hot water OFF
3 = central heating OFF and domestic hot water ON
p4 Eco or comfort mode adjustable at 3 levels:
0 = comfort setting
1 = eco mode
2 = regulated by controller (= factory setting)
p5 Anticipated current for on/off thermostat (ask your ser-
vice engineer for further details)
0 = no anticipated current (= factory setting)
1 = anticipated current
p6 Display off automatically
0 = display stays off
1 = display stays on
2 = display switches off automatically after 3 minutes
(= factory setting)
Changing P1 setting: flow temperature of water in central
heating system
Reduce the flow temperature as follows:
Press 'Enter'- key until codes p [ and [ 1 are dis-
played alternately.
Press 'Enter'- key again; set value for maximum flow
temperature is displayed: 75°C (factory setting).
Press [+] or [-] -key to change this value, for example to
70°C.
Press 'Enter'- key to confirm value; codes p [ and [
1 are displayed alternately.
Press 'Reset'- key to switch boiler to operating mode.
Summer holidays
In summer a reduced flow temperature setting may be ade
quate for your heat requirement. Reduce the flow temperature
and save energy.