Expanding The Central Heating System; Technical Data - REMEHA Avanta Plus 28c User Manual

Fully condensing high-efficiency central heating boilers
Hide thumbs Also See for Avanta Plus 28c:
Table of Contents

Advertisement

10

EXPANDING THE CENTRAL HEATING SYSTEM

11

TECHNICAL DATA

Appliance type Remeha Avanta Plus
General
Boiler control
Nominal central heating capacity (80/60°C)
Assembly dry weight
Noise level at distance of 1m from the boiler (at full load)
Gas and flue details
Gas consumption natural gas
Gas flue rate
CH side
Water capacity
Minimum operating water pressure
Maximum operating water pressure PMS
Water temperature
Operating temperature
Domestic hot water side
Tap capacity (35°C)
Minimum tap flow
2)
Electrical
Main supply
Power consumption W
Degree of protection
maximum
heat exchanger and piping
maximum
maximum
)
1
maximum
Remeha Avanta Plus
Connecting thermostats
A 2-wire on/off thermostat (e.g. the Remeha Celcia 10) or to a
modulating thermostat (e.g. the Remeha Celcia 15 or 20) can
be connected to the Avanta Plus. Consult the installer about
connecting the thermostat you have chosen.
Connecting an under floor heating system
A under floor heating system can be directly connected to the
Avanta Plus (provided it is sealed to prevent oxygen diffusion).
Consult the installer about connecting to a floor heating sys-
tem.
Use of solar panels
The Remeha Avanta Plus is suitable for use as a post-heater
for solar panels. Consult the installer about installing a solar
panel.
kW
kg
dB(A)
m
/h
3
n
kg/h
l
bar
bar
°C
°C
l/min
l/min
V/Hz
W
IP
= a modulating boiler permits infinitely adjustable matching
1)
of heat production to heat demand.
= minimum flow rate of water from the tap to start the boiler
2)
running.
= splash proof; under certain circumstances the boiler may
3)
be installed in damp rooms such as bathrooms. Check
with
your installer.
= noise level of a quiet conversation.
4)
26
24s
28c
system
combi
on/off or modulating
21.6
21.6
29.0
30.5
< 44
4)
2.3
3.0
37
47
1.8
1.8
0.8
3.0
110
95
-
11.4
-
1.2
230 / 50
115
115
X4D
3)
39c
combi
1)
33.3
34.5
3.9
62
2.2
15.9
1.2
180

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avanta plus 39cAvanta plus 24s

Table of Contents