3

OPERATING THE BOILER

1
LTALW7H000222a
LT.AL.W7H.000.222
R
2
3
4
5
LTALW7H000203a
LT.AL.W7H.000.203
Remeha Avanta Plus
2.2

Controls

The Remeha Avanta Plus is a fully modulating boiler and can
be controlled using one or more of the following methods;
1.
Open Therm – 2 wire interface compatible with
the Remeha Celcia 15 room compensator and the
Remeha Celcia 20 outside weather compensator or
with any other OpenTherm control.
2.
Open Therm thermostat in combination with 230 V
time clock.
3.
On/Off room thermostat – volt free (Celcia 10)
4.
On/Off room thermostat – 230 V
5.
230 V Switching time clock - Internal 230 V Broag
option or any other external two channel 230 V
switching clock.
2.2.1
Advanced boiler control ('abc
An intelligent advanced boiler control ('abc
monitors the boiler conditions and ensures a very reliable sup-
ply of heat. In the event of problems with water and air flow,
the boiler will temporarily switch off (depending on the nature
of the circumstances), and then after a short while simply try
again.
The control panel of the Avanta Plus has 4 function keys and a
display. The function keys are used to read or change settings
and temperatures (see par.3.3; 'Changing settings').
1 Display
2 'Reset'-key
3 [-] key
4 [+] key
5 'Enter' key
The display has two positions and displays information on the
current operating status of the boiler and any errors.
Numbers, dots and/or letters can appear in the display. The
symbols above the function keys indicate what the function of
that particular key then is. If no key is pressed for longer than
three minutes with the "boiler in stand-by mode", only one
dot is lit. With the "boiler operating", two dots are displayed.
Press any key and the current boiler status and operation
code will appear in the display.
In the event of a fault, the fault code is displayed instead
of the dots.
6