Bleeding the central heating system

A gurgling noise in pipes and/or radiators which only partially
heat up indicate(s) air in pipes and radiators. The central heat-
ing system has to be bled.
Before bleeding, the following preparations have to be made:
Open all radiator valves and set the room thermostat as
high as possible; wait until the radiators feel hot.
Switch off the boiler and wait approx. 10 minutes until the
radiators feel cold.
Bleed the central heating system as follows:
Bleed the lowest radiator first and then work towards the
highest radiator.