ENABLING THE BOILER

1,5 ... 2 bar
LTALW7H000211a
LT.AL.W7H.000.211
R
LT.AL.W7H.000.223
LTALW7H000223a
The boiler will now automatically start operating. See par. 3.2
for an explanation of the codes on the display.
LT.AL.W7H.000.212
LTALW7H000212a
 Error message
If the boiler does not start operating and an error message is
displayed, consult the error table in par. 4.1 and, if necessary,
consult the installer.
R
LT.NL.W6H.000.079
LTNLW6H000079A
22
Remeha Avanta Plus
Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up
with water, see par.5.1.
Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
- A display test will briefly appear showing all segments of
the display.
f[ xx software version;
p[ xx parameter version;
- A venting cycle of 2 minutes now follows, the version
numbers will be displayed alternately;
- Next, the following will appear in the display;
[1 ; boiler is ventilating;
[2 ; boiler is igniting;
[4 ; boiler is operating for DHW;
[7 ; boiler pump is running after heating DHW;
[0 ; boiler is stand-by.
Set the room thermostat to the desired room temperature.