Download Print this page

Epever STI200 User Manual page 14

Power frequency pure sine wave inverter sti series

Advertisement

switch‟, when the input voltage is higher than low voltage protect
value.
Low Voltage
Protect Value
Low Voltage
Recover Value
Input Over Voltage Protection
The output is switched off when the input voltage is higher than
over voltage shut off value, also the output is auto-switched on when
the input voltage drops below over voltage recover value.
Over Voltage Shut
Off Value
Over Voltage
Recover Value
Fault Protection
The inverter will shut down when the output voltage is error or
when the inverter has inner fault.
12V
10.5
13
12V
16
15
10
24V
48V
21
26
24V
48V
32
30
42
52
64
60

Hide quick links: