Oki OKIFAX 5750 Service Manual page 828

Facsimile machine
Hide thumbs Also See for OKIFAX 5750:
Table of Contents

Advertisement

The analog image data from the image sensor is amplified about 4.3 times in the external non-reverse amplifier circuit and the amplified analog data is input to
this LSI chip. In this LSI chip, the analog data is converted to digital data by the built-in A/D converter and the digital data is corrected by the internal correction
function, thus sending binary-coded data to the IOGA5 every eighth pixel normally. When contrast is corrected, multi-valued data is sent for each pixel. When
horizontal scanning lines are skipped, a request is suppressed every three requests. A sensor drive signal (CLK1) and motor synchronizing signal (SH) are output
to the image sensor.
The timing of data transfer to/from the IOGA5 is shown below.
Copyright 2000, Oki Data, Division of OKI America, Inc. All rights reserved. See the Oki Data Business Partner Exchange
(BPX) for any updates to this material. (http://bpx.okidata.com)