Ieee 1284 Parallel (Bidirectional) Submenu; Framing Errors - Printronix N7000 H-Series User Manual

Cartridge ribbon printer
Table of Contents

Advertisement

Framing Errors

Possible errors that can occur when the printer's serial interface settings do
not match those of the host computer.
Enable (default). If a framing error occurs, a fault message will display on
the control panel.
Disable. If a framing error occurs, a fault message will not display on the
control panel.

IEEE 1284 Parallel (Bidirectional) Submenu

IEEE 1284
(from page 66)
Prime
TOF
Signal
Action
Enable*
Reset*
Disable
Do Nothing
The IEEE 1284 interface is faster and more versatile than Centronics and
supports bidirectional communication. Configuration of this interface is
controlled from the host. Refer to "IEEE 1284 Parallel Interface" on page 164
more details about the available modes (Compatibility, Nibble, and Byte).
Prime Signal
Enable (default). The parallel port will perform a warm start (reboot) if the
host asserts the prime signal.
Disable. The parallel port will not perform a warm start (reboot) if the host
asserts the prime signal.
TOF Action
Reset (default). A form feed is performed before a warm start when the
prime signal is asserted from the host. This setting is used only if the
prime signal parameter is enabled.
Do Nothing. Nothing occurs before a warm start when the prime signal is
asserted from the host.
IEEE 1284 Parallel (Bidirectional) Submenu
* = Factory Default
1
H-Series have an extended range to 256.
Buffer Size
Auto
1
in K
Trickle
16*
Disable*
1-16
Enable
Trickle
Offline
Time
Process
1/4 sec*
Disable*
1/2 sec
Enable
1 sec
2 sec
4 sec
8 sec
16 sec
Off
79