Center Display Messages
These are some of the messages you may see on the center display.
Interlock (Some models only)
Spa is deactivated. Designates a self-protective mode when low voltage or supply noise is present.
Press the Mode [#] pad to reset.
Battery backup
Power has been cut off to the spa, and it is using its battery backup to preserve its settings
[15 to 20 minutes]. The control panel will be disabled until power returns to the unit.
Overheat protection
Spa is deactivated. If a malfunction occurs and spa water reaches 112
completely shut down. In such a condition, DO NOT ENTER WATER! Turn off all power to the spa
and contact your dealer or service organization. Overheating may also occur if you set the low-speed pump
to operate for extended periods of time in Economy mode. In this instance, remove the spa cover and allow
o
the water to cool to below 110
the set temperature, touch the blower pad to cool the spa.
Freeze protection
If a freeze condition is detected, both pumps are automatically activated. This is a normal spa func-
tion; no corrective action is necessary. Freeze protection is enabled regardless of the spa's status.
Flow switch
If constantly displayed, a pressure switch has malfunctioned. Contact your dealer or service organiza-
tion. If the flow message is flashing: 1- The filter may be plugged. Remove the filter and clean. 2-
The amount of water may be inadequate. Be sure the spa is properly filled. 3- A pressure switch has
malfunctioned. The spa will operate, but the heater will not activate. Contact your dealer or qualified
service organization.
Temperature set back
If spa water is more than 20
activate to provide freeze protection. This is a normal function; no corrective action is needed.
Open Sensor
Spa is deactivated. The high-limit temperature sensor is not working. This must be repaired only
by a dealer or a qualified service organization.
Open Sensor
Spa is deactivated. The water temperature sensor is not working. This also must be repaired by a
dealer or qualified service organization.
F. Touch the mode [#] pad to reset the system. If the water is still hotter than
o
F cooler than the temperature set point, the heater will automatically
o
F, the system will