Emerald Whirlpool Spa Owner's Manual
Spa Side Control
Overheat protection
o
If a malfunction occurs and spa water reaches 112
F, or the high-limit sensor has detected
Panel DS-2
o
118
F at the heater the spa is deactivated. In such a condition, DO NOT ENTER WATER!
(continued)
o
Remove the spa cover and allow the water to cool. At 110
F the spa should automatically
reset. If the spa does not reset, shut off power to the spa and call your dealer or service
organization.
Freeze protection
If a freeze condition is detected, the pumps are automatically activated. This is a normal
spa function; no action is necessary. Freeze protection is enabled regardless of the spa's
status.
Flow switch
If constantly displayed, a pressure switch has malfunctioned. Contact your dealer or service
organization. If the flow message is flashing : the filter may need cleaning, the water level
may be low, or the T-valves may need to be opened.
Temperature set back
o
If spa water is more than 20
F cooler than the temperature last set, no action is required.
Spa is functioning properly.
Open Sensor
Spa is deactivated. The high-limit temperature sensor is not working. This must be
repaired only by a dealer or a qualified service organization.
Open Sensor
Spa is deactivated. The water temperature sensor is not working. This also must be
repaired by a dealer or qualified service organization.
Standby
Spa is deactivated. The spa can be shut down when the filter needs to be replaced. Press
the "Warm" or "Cool" pad, then the "Light" pad, and all spa functions will be disabled except
for freeze control. Press any panel button to resume spa operation.