Features and Controls
Preset Filter Cycles
Spa Side Control
Panel SS-3D
Your spa will automatically filter itself twice each day. The first filter cycle will begin one minute after the
(Continued)
spa is energized. The second filter cycle will begin twelve hours later. To clean out the blower lines, the air
jets will run for 30 seconds at the start of the first filter cycle. During filtration, the low-speed pump will
activate. The ozone generator (if installed) will run on low pump demand. Filter duration is programmable
via the topside panel.
Setting the Filter Cycles
Press the "Set" pad, then the "Jets" pad, and "F3" will be displayed on the panel. "F3" is the default filter
time and indicates a 3 hour cycle. Press the "Set" pad again to cycle through the rest of the filter time
options; "F6" = 6 hours, "F9" = 9 hours, and "FC" = 12 hours. After you have selected your duration, press
the "Jets" pad again to exit the programming mode.

Safety Features

Overheat Protection (Spa is deactivated)
If your spa should overheat, the display will flash {OH}. In such a condition, DO NOT ENTER THE
WATER. Turn off all power to the spa and contact your dealer or service organization. Overheating may
also occur if the filter duration is set too long at the time of installation. To reset the spa, press any panel
button.
Flow Switch Detection
If a pressure switch malfunctions, the display will show {FL}. Contact your dealer or service organization.
Open Sensor (Spa is deactivated)
If the high-limit sensor or water temperature sensor malfunctions, the display will show {Sn}. Contact your
dealer or service organization.