Coffee System Cleaning; Weekly Cleaning - Schaerer Siena 1/2 User Manual

Table of Contents

Advertisement

www.schaerer.com

Coffee system cleaning:

2
(Siena 1 / Siena 2)
2a
► Fill the water tank with fresh water.
► Empty the drip tray and place a contain-
er (Volume: ± 1.5 Litre) under the outlet.
► If „Tablet" already appears on the display
don't press the
button! Otherwise
press the
button for 4 seconds, until
following message displays:
Tablet

Weekly cleaning:

4
(Siena 1 / Siena 2)
4a
► Press the
button to enter the Stand-
by mode.
► Open the service door at the side.
► Pull out the drawer (Press „Press") and lift
out the brewer.
► Clean the brewer under warm running
water.
Never clean brewer in the dish
washer! The brewer has to be dry
before it is placed back in!
Observe all hygiene regulations according to HACCP!
Extract from HACCP:
• Never top up milk! Always throw leftovers away.
• Use milk from its original packing!
• Always clean the milk container before filling it with fresh milk.
• Fill up with fresh milk, chilled to 3 °C - 5 °C, just before restarting the machine!
• The milk must be homogonised! Use pasteurized or ultra high temperature treated (UHT) milk! Do not use raw milk!
• For optimum hygiene use a refrigerator (optional) to maintain milk temperature.
• Clean the refrigerator/cooling element (optional) at least once a week if the machine is equipped with one!
58
2b
► Insert the cleaning tablet into the funnel.
► Press the
button.
Cleaning programme is running!
(duration: ± 5 minutes)
Wait until the display shows:
Ready
4b
► Remove and clean the plastic tray.
► Remove the coffee grounds in the brew-
er area using a vacuum cleaner or the
brush.
► Re-place the plastic tray and the brewer.
► Press the
button to switch-on the
machine.
Siena 1:
► Brewer cleaning is finished.
If the function indicator
ing the brewer is not right in place
or the door is not closed properly.
Milk system rinsing:
3
(Siena 2)
3a
► Put the milk tube into a container with
fresh water (± 150 ml).
► Place a container (Volume: ± 200 ml) un-
der the outlet.
► Press the
Milk system rinsing is running!
(duration: ± 40 seconds)
Wait until the display shows:
Ready
4c
Siena 2:
► Clean the foam nozzle (see picture) with
the supplied instrument (Art.-No.: 061454)
is blink-
Cleaning
button twice.
BASI 2 - EN
Version 04
08.2007