5.
HORN LEVEL
12. BASS LEVEL
The Volume of each Rotor is set. The setting range is 0 to -12dB.
6.
RISE TIME - HORN
13. RISE TIME - BASS
Here the Time is set for the Rotor to reach the Fast Speed, when you go from
Slow or Break to Fast state. The setting range for the Horn Rotor is 0.2 - 5.0s,
and that for the Bass Rotor is 0.5 - 12.5s.
7.
FALL TIME - HORN
14. FALL TIME - BASS
Here the Time is set for the Rotor to reach the Slow speed, when you go from
Fast to Slow Speed. The setting range for the Horn Rotor is 0.2 - 5.0s, and that
for the Bass Rotor is 0.5 - 12.5s.
8.
BREAK TIME - HORN
15. BREAK TIME - BASS
Here the Time is set for the Rotor to stop, when you go from Fast state to
Break. The setting range for the Horn Rotor is 0.2 - 5.0s, and that for the Bass
Rotor is 0.5 - 12.5s.
9.
HORN CHARACTER
Here the Tone of the Horn Rotor is set.
"FLAT" is a flat tone, and the others are the tones with each "peaky" character-
istic.
16. MIC - ANGLE
This is the parameter to set the LOCATIONS of the two Microphones for the
imaginary Leslie Speaker.
The ANGLE decides the distance between the two mikes.
The setting range is 0 - 180 degrees. The farther, the more stereophonic feeling
it gives.
17. MIC - DISTANCE
This is the parameter to set the DISTANCE between the imaginary Leslie
Speaker and the Microphones.
The setting range is 0.3 - 2.7m. The more the value increases, the less effective
it gets.
NOTE:
When you operate the parameters 2 - 17, the setting range will be lost
after the power is switched off, if you do not do the recording operation
of the next page.
EXTERNAL LESLIE SPEAKER
18. LESLIE CHANNEL
The Channel is set for the Leslie Speaker connected to the 11-pin terminal.
At "1", the sounds always comes out of the Rotary Channel.
At "2 or 3", the sounds are put out to the stationary channel when the
[LESLIE] button gets OFF and the [BREAK] button gets OFF. Otherwise, the
sound comes out of the Rotary Channel.
CHANNELS OF CURRENT LESLIE MODELS
122XB:
1ch
2101/2102: 3ch
Setting the Parameters