Expansion Card Functions
"P" parameters will be appeared when the expansion option is connected.
Func.
Code
Reaction when option card
P001
error occurs
[EA] terminal selection
P003
Pulse train input mode
P004
selection for feedback
Encoder pulse setting
P011
Simple positioning selection
P012
Creep Speed
p015
Over-speed error detection
P026
level
Speed deviation error
P027
detection level
P031
Torque command input
P033
selection
Torque command level input
P034
Torque bias mode selection
p036
Torque bias value setting
p037
Torque bias polar selection
p038
Speed limit of Torque control
p039
(Forward rotation)
Speed limit of Torque control
p040
(Forward rotation)
CALL NOW 800-985-6929
http://www.automatedpt.com
"P" Function
Name
Two option codes:
00...Inverter trips
01...Ignores the error (Inverter
continues operation)
Three option codes:
00...Speed reference (incl. PID)
01...For control with encoder
feedback
02...Extended terminal for EzSQ
Four option codes:
00...Single-phase pulse [EA]
01...2-phase pulse (90° difference) 1
([EA] and [EB])
02...2-phase pulse (90° difference) 2
([EA] and [EB])
03...Single-phase pulse [EA] and
direction signal [EB]
Sets the pulse number (ppr) of the
encoder, set range is 32~1024
pulses
Two option codes:
00...simple positioning deactivated
01...simple positioning activated
Set range is start frequency (b082)
~10.00 Hz
Set range is 0~150%
Set range is 0~120 Hz
Six option codes:
00...Analog voltage input [O]
01...Analog current input [OI]
03...Operator, 06...Option
Set range is 0~200%
Five option codes:
00...No bias
Range is –200~200%
Two option codes:
00...According to the sign
01...According to the rotation
direction
05...Option
Set range is 0.00~120.00Hz
Set range is 0.00~120.00Hz
http://www.automatedpt.com
Description
01...Operator
81
Email: charles@automatedpt.com
Run
Defaults
Mode
Lnitial data
Units
Edit
00
-
00
-
00
-
512.
-
00
-
5.00
Hz
115.0
%
10.00
Hz
00
-
0.
%
00
-
0.
%
00
-
0.00
Hz
0.00
Hz
Email: charles@automatedpt.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents