Hitachi WJ200 Series Quick Reference Manual page 73

Wj200 series inverter single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
Func.
Code
Logic output 2 operator
C147
Logic output 3 operand A
C148
Logic output 3 operand B
C149
Logic output 3 operator
C150
Input [1] response time
C160
Input [2] response time
C161
Input [3] response time
C162
Input [4] response time
C163
Input [5] response time
C164
Input [6] response time
C165
Input [7] response time
C166
Multistage speed/position
C169
determination time
Input Function Summary Table – This table shows all thirty-one intelligent input functions
at a glance. Detailed description of these functions, related parameters and settings, and
example wiring diagrams are in "Using Intelligent Input Terminals" on page 4-8.
Option
Code
00
01
02
03
04
05
06
07
08
CALL NOW 800-985-6929
http://www.automatedpt.com
"C" Function
Name
Input Function Summary Table
Terminal
Function Name
Symbol
FW
FORWARD Run/Stop
RV
Reverse Run/Stop
Multi-speed Select,
CF1 *1
Bit 0 (LSB)
Multi-speed Select,
CF2
Bit 1
Multi-speed Select,
CF3
Bit 2
Multi-speed Select,
CF4
Bit 3 (MSB)
JG
Jogging
DB
External DC braking
Set (select) 2nd Motor
SET
Data
http://www.automatedpt.com
Description
Applies a logic function to calculate
[LOG] output state,
Three options:
00...[LOG] = A AND B
01...[LOG] = A OR B
02...[LOG] = A XOR B
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
Applies a logic function to calculate
[LOG] output state,
Three options:
00...[LOG] = A AND B
01...[LOG] = A OR B
02...[LOG] = A XOR B
Sets response time of each input
terminal, set range:
0 (x 2 [ms]) to 200 (x 2 [ms])
(0 to 400 [ms])
Set range is 0. to 200. (x 10ms)
ON
Inverter is in Run Mode, motor runs forward
OFF
Inverter is in Stop Mode, motor stops
ON
Inverter is in Run Mode, motor runs reverse
OFF
Inverter is in Stop Mode, motor stops
ON
Binary encoded speed select, Bit 0, logical 1
OFF
Binary encoded speed select, Bit 0, logical 0
ON
Binary encoded speed select, Bit 1, logical 1
OFF
Binary encoded speed select, Bit 1, logical 0
ON
Binary encoded speed select, Bit 2, logical 1
OFF
Binary encoded speed select, Bit 2, logical 0
ON
Binary encoded speed select, Bit 3, logical 1
OFF
Binary encoded speed select, Bit 3, logical 0
Inverter is in Run Mode, output to motor runs at
ON
jog parameter frequency
OFF
Inverter is in Stop Mode
ON
DC braking will be applied during deceleration
OFF
DC braking will not be applied
The inverter uses 2nd motor parameters for
ON
generating frequency output to motor
The inverter uses 1st (main) motor parameters
OFF
for generating frequency output to motor
71
Email: charles@automatedpt.com
Run
Defaults
Mode
Lnitial data
Edit
00
00
01
00
1.
1.
1.
1.
1.
1.
1.
0.
Description
Email: charles@automatedpt.com
Units
ms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents