Flir Systems, Inc - FLIR PTZ-35 MS Installation And Operation Manual

High resolution multi sensor camera
Hide thumbs Also See for PTZ-35 MS:
Table of Contents

Advertisement

Examples:
IR Imager Status Byte
The status byte (Byte 2) of all commands to the IR Imager should, under normal operating
conditions, contain 00
with the following table:
Status Byte
Value (hex)
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x09
0x0A
IR Imager Commands / Responses:
Command Value Command Word
No-Op
6E0000000000DFBB0000
Set Camera
6E0000010000EB8B0000
Defaults
Reset
6E000003000086EB0000
Factory
Defaults
Get Serial
6E0000650000AF200000
Number
Get Version
6E0000050000344B0000
Set FFC
Mode
Auto
6E00000B00020F0800000000
Manual
6E00000B00020F0800011022
Do FFC
6E00000C0000AADA0000
E-Zoom
1x
6E00000F0002D3C800000000
427-0016-00-10 Revision 120
If data byte count = 0, total string bytes = 10
If data byte count = 8, total string bytes = 18
. For all responses, the thermal imager will set the status byte in accordance
H
Definition
CAM_OK
CAM _BUSY
CAM _NOT_READY
CAM _RANGE_ERROR
CAM _CHECKSUM_ERROR
CAM _UNDEFINED_PROCESS_ERROR
CAM _UNDEFINED_FUNCTION_ERROR
CAM _TIMEOUT_ERROR
CAM _BYTE_COUNT_ERROR
CAM _FEATURE_NOT_ENABLED
Description
Function executed
Camera busy processing serial
command
Camera not ready to execute
specified serial command
Data out of range
Header or message-body
checksum error
Unknown process code
Unknown function code
Timeout executing serial
command
Byte count incorrect for the
function code
Function code not enabled in the
current configuration.
System Response
6E0000000000DFBB0000
6E0000010000EB8B0000
6E000003000086EB0000
6E0000650004EFA4000(aabbccdd)0E
6E0000050008B543(abcdefghijklmnop)0DF7
6E00000B00020F0800000000
6E00000B00020F0800011022
6E00000F0002D3C800000000
Copyright © 2008 FLIR Systems, Inc.
Notes
S/N aabbccdd
Software
ab.cd.ef.gh
FPGA
ij.kl.mn.op