Location Codes Displayed By Diagnostics - IBM F10 Service Manual

Fibre channel raid storage server and expandable storage unit, 2102
Hide thumbs Also See for F10:
Table of Contents

Advertisement

Table 5. AIX Error Codes (continued)
EC
FRU
999203
The list of possible failing FRUs depends
on the enclosure identified in the
diagnostic failure information (See
"Location Codes Displayed By
Diagnostics"):
Controller Module (EID E0):
v Controller Fan - see "Replacing a
Failed Controller Fan" on page 106.
v Controller Power Supply Fan - see
"Replacing a Failed Power Supply Fan"
on page 109.
v Controller Backpanel - see "Replacing
a Failed Controller Backpanel" on
page 98.
Drive Drawer (EID E2 - E6):
v Device Drawer Fan - see "Replace a
Failed Fan" on page 188.
v Device Drawer ESM module - see
"Replace a Failed ESM FRU" on
page 170.
v Device Drawer Midplane/Chassis - see
"Replace a Failed MidPlane" on
page 173.

Location Codes Displayed By Diagnostics

When the AIX diagnostics detect a failure in the 2102 Fibre Channel RAID
subsystem, the failure information includes a location code used to physically
identify the failing component within the subsystem. The following describes how to
interpret the reported location codes:
v Translating location codes for a disk drive failure:
v Translating location codes for other subsystem component failures (other
Disk drive failures will be reported in the following format:
653153: Drive failed by user via Mode Select.
Refer to the 2102 Model F10 Service Guide for more information.
100%
17.357GB
Location code CH5 ID8 D0 indicates that the failing disk drive is on channel 5,
SCSI ID 8 and is assigned to dac0.
than disk drives):
Subsystem component failures, other than disk drives, will be reported in the
following format:
555203: Enclosure status reports a non-critical fan failure.
Refer to the 2102 Model F10 Service Guide for more information.
100%
E6 D0
Fan module
Location code E6 D0 means the fan is in the enclosure with EID=6 and assigned
to dac0.
Description
Enclosure status reports that the subsystem is operating at
higher than normal temperature.
Action:
v For Controller Module fan failures, read the procedure
"Determining Which Fan Failed" on page 102 and replace
FRUs as instructed. If the problem persists, replace the
controller backpanel.
v For Drive Drawer fan failures, replace the Device Drawer
Fan. If the problem persists, replace the ESM. If the
problem still persists, replace the device drawer
midplane/chassis.
CH5 ID8 D0
Disk module
Chapter 1. Maintenance Starting Points
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

D002102 f102102 d00

Table of Contents