1. There is at least 1 PDU outlet available for each module (controller, drive or
2. If there is only a single PDU in the rack, but an outlet is available, then each
3. If there is only a single PDU in the rack and each controller module power
4. If there are 2 PDUs in the rack, then each controller module power supply
5. If there are 2 PDUs in the rack and each controller module power supply is

Interface Connectors and Cables

The controller module supports the following interface protocols:
v Host interface – Fibre Channel (copper wire or fiber optic), one per controller
v Drive interface – LVD-SCSI (low-voltage differential, small computer system
v Diagnostic interface – Ethernet or RS-232 (serial), one each per controller
Connectors and Host IDs
The host ID switches and connectors for interface cables are on the connector plate
(Figure 3), located on the back of the controller module.
Figure 3. Interface Connections on Controller Module
hub) in the rack. This is the minimum requirement.
controller module power supply should be connected to a different PDU outlet.
supply is connected to a separate PDU outlet and there are still outlets
available, then each device module power supply should be connected to a
separate PDU outlet until no more outlets are available.
should be connected to a different PDU.
connected to a different PDU and there are still outlets available, then each
device module power supply should be connected to a different PDU until there
are no more outlets available.
interface), six drive channels
Chapter 2. Installation And Removal Guide
41