4.2.11 Carriage Unit Removal

1.
Remove HOUSING. (Refer to Section 4.2.1)
2.
Disconnect the head FFC from the printhead. (Refer to Section 4.2.4.)
3.
Remove the Tension Spring 1.494 hanging SCALE, CR to the left side of
FRAME, TOP. Then remove SCALE, CR.
TENSION SPRING, 1.494
Figure 4-46. Remove the Tension Spring 1.491& CR Encoder Slit
4.
Loosen the Timing Belt by pushing HOLDER, PULLEY, DRIVEN and disengage
the belt from the pulley of the CR motor. (Refer to Figure 4-20.)
DISASSEMBLY AND ASSEMBLY
5.
SCALE, CR
6.
7.
Disassembly Procedures
Push PULLEY, DRIVEN down and remove it from HOLDER, PULLEY,
DRIVEN.
HOLDER, PULLEY,
Figure 4-47. PULLEY, DRIVEN Removal
Remove the Timing Belt from PULLEY, DRIVEN.
Remove LEVER, PG by releasing its hooks from the cutouts in the right side of
FRAME, TOP. Then remove the LEVER, PG.
FRAME, TOP
Hooks
Figure 4-48. LEVER, PG Removal
Revision C
PULLEY, DRIVEN
LEVER, PG
107