7.
Fit the round cutouts in SCALE, PF to the protrusions on SPUR GEAR (76)
making sure the scale and the gear are parallel. But note you don't attach the scale
to the gear yet.
8.
Attach SCALE, PF to the gear using "Scale PF unit Assembling tool" (AS tool
code: 1051767).
SPUR GEAR, 76
SCALE, PF
Figure 4-63. Loop Scale Installation
DISASSEMBLY AND ASSEMBLY
Protrusions
Tool (#1051767)
Disassembly Procedures
n
Check that the protrusions on the gear (76) are sticking out
C H E C K
from the cutouts in the scale.
P O I N T
n
Ensure SCALE, PF is free form any dirt or damage.
Revision C
Protrusion
Cutout