QDR InfiniBand Switch Platform User Manual
Note: The distance between the vertical supports in the rack must be at least 10cm longer than
the switch.
3.
Determine which side of the rack (front or back) will need the plug end and which side of the
rack will need the socket end. If you have only one power supply unit, determine which side
of the rack (left or right) will need the power cord.
Note: The primary PSU is on the right side of the power side of the switch.
4.
Put the power cables through the 1U space for the switch.
Note: Make sure that they are extending from both sides of the rack.
5.
Clip the 4 caged nuts into the holes in the rack you will be using to connect the rail slides.
Check that both sides of the switch, left and right, are the same level in the rack.
Figure 38: Full Rack
1U space
Figure 39: Inserting the Caged Nuts
20
...
...
...
.
The caged nuts
are separated by
a single space
Mellanox Technologies
Rev 2.9
63