Parallel Interface (Option)
Specifications
Transmission mode
8-bit parallel data
Receive buffer size
16 kB
Compatible mode:
Transmission modes
It is an asynchronous forward direction of the byte
width (from host to printer) channel, and the interface
line of the data is operated in accordance with signal
line definitions of Centronics.
NIBBLE mode:
Nibble mode is asynchronous reverse channel
communication with data transmission controlled by
the host computer. In reverse channel transmission, the
data is nibble transmitted in two parts using four status
lines (Fault, Select, PE, and Busy). And nibble mode can
be used along with compatible mode to send data in
two directions.
ECP mode:
ECP mode permits bi-directional asynchronous data
transmission, and thanks to its interlock handshake, it
does not require the timing necessary with compatible
mode.
Signal level
IEEE1284 standard
Signal line and pin assignment table
Pin No. Signal name
1
*STROBE
Input
2-9
DATA1-8
Input
10
*ACKNLG
Output
11
BUSY
Output
12
PERROR
Output
13
SELECT
Output
14
*AUTOFD
Input
15
NC
16
GND
17
FGND
18
P.L.H
Output
19-30
GND
31
*INIT
Input
32
*FAULT
Output
33-35
NC
36
*SELECTIN
Input
60
I/O
Function
Strobe signal to read in 8-bit data
8-bit parallel signal
8-bit data request signal
Signal specifying printer busy
Signal specifying media out
Signal specifying if the printer is on-line
(printing enabled) or off-line (pausing)
Invalid (ignored)
-
Not used
-
Signal ground
-
Frame ground
Peripheral logic high (pull up to +5 V at 10 kΩ)
-
Ground for twisted pair return
Printer reset
Signal specifying printer error
-
Not used
Invalid (ignored)