18
The Subnet management features include:
upgrading Drivers
upgrading software
monitoring of:
AC power to the PSUs
DC power out from the PSUs
board temperature
spine fan module unit
leaf fan module unit
failure in the switch system
system failure in the switch system
querying for board serial numbers and their revisions
In addition, the tools enable firmware management capabilities such as:
querying for existing firmware versions
burning new firmware (from scratch or for recovery from damaged firmware)
querying for and changing system GUIDs
checking for duplicate or bad GUIDs
3.3.1 Embedded Cluster Management ECM
The ECM tools are included in the management module and are accessed through:
KVM
SSH
Telnet
the WEB
Connection is made through either the video and USB connectors for KVM or the ethernet connector.
See the Embedded Tools user manual included on the CD for further instructions.

3.3.2 Accessing the management CPU

There are two ways to access the management CPU:
via KVM connections locally
via the Ethernet connector for remote access
Management modules with a CPU will have the capability to allow remote monitoring and remote man-
agement of the chassis from any host connected to the fabric.
If the connection will be through the web then the host will need the capability to connect to the web.
3.3.2.1 Accessing the CPU via Keyboard, Video, Mouse (KVM)
For local access out of band management of the switch system:
1.
Connect a keyboard to the one of the USB ports, a video device to the video connector, and a mouse to
the second USB connector of the switch (cables not supplied).