2.2.2 Mechanical Installation

The switch platform uses a rack mounted switch designed for installation in a standard 19" rack with all
ports on the rear of the enclosure. The front of the switch includes a hot-swap power supply module (with an
optional second PSU for redundancy), hot-swap fan tray, and I/O ports for an optional CPU advanced man-
agement board and an I2C I/O port. The hot-swap fan module provides front to back air flow.
The switch platform contains auto-sensing 90 - 264 VAC connections for all possible PSUs.
Rev 1.5
Copper InfiniBand cables are heavy and not flexible, as such they should be
carefully attached to or detached from the connectors. Refer to the cable manu-
facturer for special warnings and instructions.
When this product is mounted or serviced in a rack, special precautions must be
taken to ensure that the system remains stable. In general you should fill the
rack with equipment starting from the bottom to the top.
This equipment should be installed, replaced, or serviced only by trained and
qualified personnel.
Disposal of this equipment should be in accordance to all national laws and reg-
ulations.
This equipment should be installed in compliance with local and national elec-
trical codes.
There is a risk of explosion should the battery be replaced with a battery of an incor-
rect type.
Dispose of used batteries according to the instructions.