Specifications; Environmental Specifications; Mechanical Specifications - HP PROLIANT ML330 G6 User Manual

Hewlett-packard server user manual
Hide thumbs Also See for PROLIANT ML330 G6:
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature
Operating
1
Non-operating
Maximum rate of temperature
change
Operating
2,3
Non-operating
Relative humidity
(noncondensing)***
Operating
Non-operating
Maximum wet bulb
temperature (non-condensing)
Operating
Non-operating
Altitude
Operating
2
Non-operating
Maximum rate of altitude
change
Operating
Non-operating
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight is allowed.
2
The type and number of options installed can limit the upper limit.
3
System performance may be reduced if operating with a fan fault above 30ºC (86ºF).

Mechanical specifications

Specification
Height
Depth (without bezel)
Width
Weight (no drives installed)
Value
10°C to 35°C (50°F to 90°F)
30°C to 60°C (-22°F to 140°F)
10°C/hr (18°F/hr)
20°C/hr (36°F/hr)
10% to 90%
5% to 95%
28°C (82.4°F)
38.7°C (101.7°F)
3,050 m (10,000 ft)
9144 m (30,000 ft)
3,000 m (10,000 ft)
9,144 m (30,000 ft)
Value
20.0 cm (7.87 in)
42.70 cm (16.81 in)
61.30 cm (24.13 in)
16.04 kg (35.37 lb)
Specifications 120

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents