Environmental specifications

Specification
Temperature range
2
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
2
System performance during standard operation might degrade if there is a fan fault or if the internal server temperature is above 30°C
(86°F).

Server specifications

Dimension
Height
Depth
Width
Weight (approximate values)
Minimum (one drive and one DIMM installed, no media drive or
expansion board installed)
Maximum (four drives, two DIMMs, optical drive or SSD, and two
expansion boards installed)

Power supply specifications

The server is configured with a non-hot-plug, nonredundant 200 W power supply.
1
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
10% to 90%
28°C (82.4°F) maximum web bulb temperature
(noncondensing) across the operating temperature range
of 0°C to 40°C.
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
23.50 cm (9.25 in)
25.40 cm (10.00 in)
23.00 cm (9.06 in)
6.495 kg (14.32 lb)
9.69 kg (21.36 lb)
81