1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps: None
Possible Cause:
The integrated array enabler board failed.
The I/O board, drive backplane fan board, or drive backplane failed.
Action:
Replace the integrated array enabler board.
1.
Update the integrated Smart Array option to the latest firmware version
2.
page 65).
CAUTION: Only authorized technicians trained by HP should attempt to remove the I/O board. If you
believe the I/O board requires replacement, contact HP Technical Support before proceeding.
Reboot the server after replacing each item:
3.
Drive backplane fan board
a.
Drive backplane
b.
I/O board
c.
1777-Slot X Drive Array - ProLiant Drive Storage Enclosure Problem Detected...
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
Check cooling fan operation by placing a hand over the fan.
Be sure the internal plenum cooling fan in tower servers or storage systems is operational. If the fan
is not operating, check for obstructions and check all internal connections.
Replace unit side panel if removed.
Check the LEDs. If the ProLiant Storage System power LED is amber instead of green, this indicates a
redundant power supply failure.
If the message indicates to check SCSI cables:
Compare the cabling against the diagrams in the HP Smart Array Controller User Guide.
a.
If the routing is correct, replace cables on the specified port until the POST error message is
b.
eliminated.
1778-Drive Array Resuming Automatic Data Recovery Process
Audible Beeps: None
Possible Cause: A controller reset or power cycle occurred while Automatic Data Recovery was in
progress.
Action: No action is required.
("Firmware
maintenance" on
Error messages 118
Need help?