Ppm Problems; Processor Problems - HP ProLight Server Troubleshooting Manual

Hewlett-packard proliant servers troubleshooting guide
Table of Contents

Advertisement

Server fails to recognize new memory
Action:
Be sure the memory is the correct type for the server and is installed according to the server
1.
requirements. Refer to the server documentation or HP website (http://www.hp.com).
Be sure you have not exceeded the memory limits of the server or operating system. Refer to the
2.
server documentation.
Be sure no Event List error messages (on page 124) are displayed in the IML.
3.
Be sure the memory is properly seated.
4.
Be sure no conflicts are occurring with existing memory. Run the server setup utility.
5.
Test the memory by installing the memory into a known working server. Be sure the memory meets
6.
the requirements of the new server on which you are testing the memory.
Replace the memory. Refer to the server documentation.
7.

PPM problems

Action: If the PPMs are not integrated on the system board:
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
If applicable, check the PPM LEDs to identify if a PPM failure occurred. For information on LEDs, refer
1.
to the server documentation.
Reseat each PPM, and then restart the server.
2.
If reseating the PPMs is not effective, remove all but one PPM, restart the server to see if the PPM is
3.
working, and then install each PPM individually, cycling power each time. Follow the warnings and
cautionary information in the server documentation.

Processor problems

Action:
If applicable, check the processor LEDs to identify if a PPM failure occurred. For information on LEDs,
1.
refer to the server documentation.
Be sure each processor is supported by the server and is installed properly. Refer to the server
2.
documentation for processor requirements.
Be sure the server ROM is up to date.
3.
Be sure you are not mixing processor stepping, core speeds, or cache sizes if this is not supported
4.
on the server. Refer to the server documentation for more information.
CAUTION: Removal of some processors and heatsinks require special considerations for replacement,
while other processors and heatsinks are integrated and cannot be reused once separated. For specific
instructions for the server you are troubleshooting, refer to processor information in the server user guide.
If the server has only one processor installed, replace it with a known functional processor. If the
5.
problem is resolved after you restart the server, the original processor failed.
If the server has multiple processors installed, test each processor:
6.
Remove all but one processor from the server. Replace each with a processor terminator board or
a.
blank, if applicable to the server.
If the server includes PPMs that are not integrated on the system board, remove all PPMs from the
b.
server except for the PPM associated with the remaining processor.
Hardware problems 42

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents