NMI - Undetermined Source
Audible Beeps: None
Possible Cause: An NMI event has occurred.
Action: Reboot the server.
Node Interleaving disabled - Invalid memory configuration
Description: Each node must have the same memory configuration to enable interleaving.
Action: Populate each node with the same memory configuration and enable interleaving in RBSU.
No Floppy Drive Present
Audible Beeps: None
Possible Cause: No diskette drive is installed or a diskette drive failure has occurred.
Action:
Power down the server.
1.
Replace a failed diskette drive.
2.
Be sure a diskette drive is cabled properly, if a diskette drive exists.
3.
No Keyboard Present
Audible Beeps: None
Possible Cause: A keyboard is not connected to the server or a keyboard failure has occurred.
Action:
Power down the server, and then reconnect the keyboard.
1.
Be sure no keys are depressed or stuck.
2.
If the failure reoccurs, replace the keyboard.
3.
Parity Check 2 - System DIMM Memory
Audible Beeps: None
Possible Cause: An uncorrectable error memory event occurred in a memory DIMM.
Action: Run Insight Diagnostics
use the DIMM LEDs to identify failed DIMMs and replace the DIMMs.
PCI Bus Parity Error, PCI Slot x
Audible Beeps: None
Possible Cause: A PCI device has generated a parity error on the PCI bus.
Action: For plug-in PCI cards, remove the card. For embedded PCI devices, run Insight Diagnostics and
replace any failed components as indicated.
("HP Insight
Diagnostics" on page 61) to identify failed DIMMs. Then,
Error messages 97