Drive (Bay) X Is A Replacement Drive; Drive (Bay) X Is A Replacement Drive Marked Ok; Drive (Bay) X Is Failed; Drive (Bay) X Is Undergoing Drive Recovery - HP ProLight Server Troubleshooting Manual

Hewlett-packard proliant servers troubleshooting guide
Table of Contents

Advertisement

If the problem persists, power down the system and replace the cable.
4.
If the problem persists, power down the system and replace the drive.
5.

Drive (Bay) X is a Replacement Drive

Description: This drive has been replaced. This message is displayed if a drive is replaced in a fault-
tolerant logical volume.
Action: If the replacement was intentional, allow the drive to rebuild.

Drive (Bay) X is a Replacement Drive Marked OK

Description: The drive has been replaced and marked OK by the firmware, in one of three possible
scenarios: the drive was replaced in a non-fault-tolerant configuration; more drives were replaced than the
configured fault-tolerant-configuration mode could sustain; or the storage enclosure was powered down
before the server, preventing the drive from being rebuilt. The drive may contain incorrect data.
Action: Verify data on the drives. Always power down the server before powering down any external
drive enclosures.

Drive (Bay) X is Failed

Description: The indicated physical drive has failed.
Action:
Check for loose cable connections
1.
If cable connectors are secure, replace the drive.
2.

Drive (Bay) X is Undergoing Drive Recovery

Description: This drive is being rebuilt from the corresponding mirror or parity data.
Action: No action is required.

Drive (Bay) X Upload Code Not Readable

Description: An error occurred while ADU
the upload code information from this drive.
Action: If multiple errors occur, the drive may need to be replaced.

Drive (Bay) X Was Inadvertently Replaced

Description: The physical drive was incorrectly replaced after another drive failed.
Action:
CAUTION: Do not run the server setup utility and try to reconfigure, or data will be lost.
Power down the server.
1.
Replace the drive that was incorrectly replaced.
2.
Replace the original drive that failed.
3.
("Loose
connections" on page 15).
("Array Diagnostic
Utility" on page 63) was trying to read
Error messages 79