Command/Response Table For Special Function Sis Commands - Extron electronics ISM 482 User Manual

Integration scaling matrix switchers
Hide thumbs Also See for ISM 482:
Table of Contents

Advertisement

Programmer's Guide, cont'd
Command/response table for IP SIS commands
Command
Set ISM name (location)
Read ISM name (location)
Set GMT/date
The date and time entered should be Greenwich Mean Time (GMT).
Read GMT/date
Set IP address
Read IP address
Read hardware address
Read # of open connections
Set administrator password
Read administrator password
Set user password
Read user password
When the computer is connected to the switcher via the RS-232 link, the Admin and User password
fields are not masked. If a password has been inadvertently changed to an unknown value, you can
look up and, if desired, change a password in this window without knowing the current password.

Command/response table for special function SIS commands

The syntax for setting a special function is
(such as 35 in the first example below),
delay" in the first example below), and # is the execute command. To view a
function's setting, use
Command
Delay times
RGB delay (Triple-Action Switching)
Example:
Read RGB delay
Scaler settings
Output sync format
Example:
Read output sync format
Output polarity
Example:
Read output sync polarity
4-14
Integration Scaling Matrix Switcher • Programmer's Guide
ASCII Command
Response
(host to switcher)
(switcher to host)
CN
Ipn•
Esc X30
CN
Esc
X30
CT
Ipt•
Esc X31
CT
Esc
X32
CI
Ipi•
Esc
X33
CI
Esc
X33
CH
Esc
X35
CC
Esc
X36
CA
Ipa
Esc
X34
X34
CA
Esc
X34
CU
Ipu
Esc
X34
X34
CU
Esc
X34
# where
X?
X?
ASCII Command
Response
(host to switcher)
(switcher to host)
*
*3#
Dly
X2
X20
X2
1*35*3#
1Dly35
*3#
X2
X20
*
*6#
Syn
X2
X7
2*0*6#
Syn00
*6#
X2
X7
*
*7#
Pol
X2
X8
X8
1*1*7#
Pol01
*7#
X2
X8
Additional description
X30
X32
The switcher sends the response,
X33
but the host may not receive it.
*
# where
is the value or variable
X n
X?
X n
is the function number (such as "set RGB
X?
is the function number.
Additional description
Switching delay of the selected
X20
input to the selected output.
Adjustable in 0.01 second steps
up to 50 = 5.0 seconds. 0 = 0.0
seconds (default), 1 = 0.1
seconds, 2 = 0.2 seconds, and so
on.
RGB delay for output 1 set to 3.5
seconds.
0 = RGBHV (default).
X7
1 = RGBS.
RGBHV signal on output 2.
:Horizontal/Vertical polarity
X8
0 = H–/V–
1 = H–/V+
H–/V+ polarity on output 1.
2 = H+/V–
3 = H+/V+

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ism 182

Table of Contents