AMC2 4W
Fig. 5.10 Settings for RS-485 two wire connections
For RS-485 two wire connection set the AMC-MUX DIL-Switch
at the position 3, 7 and 8 to ON. On the upper side of the AMC
panel put the jumper on the two pins on the right hand side of
the connector 8 (see also: Figure 3.3). Set the RS-485 address
of the AMC using the DIL-Switch - see Section 5.6.3 DIL Switch
Address Selector.
5.6.2

RS-485 Four Wire Connection

Fig. 5.11 Connection scheme of an RS-485 four wire connection
Bosch Security Systems
Installation manual
Installing | en 33
F.01U.024.965 | V.4 | 2006.09