BP7359 VININGS CF240 9/19/07 11:13 AM Page 1 READ AND SAVE THESE INSTRUCTIONS VININGS ™ Ceiling Fan Owner's Manual Model Number CF240ATB00 Antique Bronze with Dark Cherry/Walnut Blades 27.0 Net Weight: Lbs. Part No. F40BP73590001 Form No. BP7359-1 U.L. Model No.: CF240...
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
Emerson Electric Co. Substitution of h. One hanger bracket parts or accessories not designated for i. One hanger ball/downrod (16”) use with this product by Emerson Electric assembly Co. could result in personal injury or property damage. j. One 8” downrod k.
Page 4
7. Sixteen 10-24 x 8mm truss head assembly. screws 8. Sixteen flat washers 9. One 1/8-27 nut 10. One metal washer 11. One rubber washer 12. One hex wrench LIGHT FAN OFF EMERSON U.L. Model No.: CF240...
IMPORTANT: Your ceiling fan will not General function properly, Your Emerson ceiling fan comes supplied damaged, if used with any wall dimmer with a Fan/Light Wall Control which switch or control other than the consists of a wall control (transmitter) and...
Page 6
BP7359 VININGS CF240 9/19/07 11:13 AM Page 6 4. Remove and retain one of the three 10-24 x 8mm TRUSS HEAD pan head screw/lockwashers from the SCREWS (3) motor flange (Figure 2); loosen the FLAT other two pan head screws three or WASHERS (3) four turns.
Page 7
BP7359 VININGS CF240 9/19/07 11:13 AM Page 7 10. Position the top and bottom halves of LIGHT FITTER ASSEMBLY the styrofoam packaging side-by-side on the floor with a six to eight inch gap LIGHT FITTER REMOVE AND RETAIN CONNECTOR between the halves (Figure 6). THREE PAN HEAD Carefully place the partially assembl- SCREW/LOCKWASHERS...
Page 8
BP7359 VININGS CF240 9/19/07 11:13 AM Page 8 12. Unscrew the two upper setscrews 13. Tighten the two upper setscrews (Figure 8) until they clear the inside of (Figure 8) securely while pulling up on the motor coupling. Then separate, the downrod.
BP7359 VININGS CF240 9/19/07 11:13 AM Page 9 How to Hang WARNING Your Ceiling Fan It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that WARNING the pin and setscrew are properly installed could result in the fan falling.
Page 10
BP7359 VININGS CF240 9/19/07 11:13 AM Page 10 WARNING WARNING Hanger bracket must seat firmly Failure to seat tab in groove could against outlet box. If the outlet box is cause damage to electrical wires and recessed, remove wall board until possible shock or fire hazard.
BP7359 VININGS CF240 9/19/07 11:13 AM Page 11 How to Wire including ground, and that no bare wire is visible at the wire connectors, except Your Ceiling Fan for the ground wire. If you feel that you do not have enough 2.
Page 12
11:13 AM Page 12 SW101 FAN/LIGHT WALL CONTROL (SUPPLIED) BLACK BLACK (HOT) BLACK LIGHT 120- FAN OFF VOLT WHITE ® EMERSON SUPPLY WHITE WHITE GROUND TWO-CONDUCTOR BLUE WHITE CABLE (WITH GROUND) BLACK GREEN WIRE (GROUND) BLUE FROM HANGER BALL AND...
Page 13
Control and Receiver LIGHT (Figure 18) BLACK FAN OFF ® EMERSON Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four NEUTRAL GROUND levers (numbered 1, 2, 3, and 4) on the...
Page 14
In new construction, only one traveler wire Is required. LIGHT 3-WAY WIRlNG DIAGRAM: FAN OFF NEW CONSTRUCTION EMERSON ® FAN/LIGHT WALL FAN/LIGHT LIGHT LIGHT WALL CONTROL...
(located on the light fitter) to the opposite position and turn LIGHT LIGHT the fan on again. The blades will turn in FAN OFF FAN OFF the opposite direction and reverse the EMERSON ® EMERSON ® airflow. FAN/LIGHT WALL CONTROL TRAVELER WIRES...
BP7359 VININGS CF240 9/19/07 11:13 AM Page 17 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1.
11:13 AM Page 18 Repair Parts LIGHT FAN OFF EMERSON Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • NAME OF ITEM •...
Page 19
BP7359 VININGS CF240 9/19/07 11:13 AM Page 19 Repair Parts Listing Part Numbers Model No. Description CF240ATB00 Hanger Pack, Consisting of: 761655-53 Hanger Bracket — Hanger Ball — Downrod (16”) — Parts Bag, Containing: 763046 Wire Connector (7) — Threaded Stud, 8-32 x 1-1/4”...
If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan.
Need help?
Do you have a question about the VININGS CF240ATB00 and is the answer not in the manual?
Questions and answers