READ AND SAVE THESE INSTRUCTIONS
CF2454WW02 CF2454BS02
CF2454PW02 CF2454BQ02
THE ODYSSEY Series
Ceiling Fan Owner's Manual
Part No. F40BP72110008
Model No.
26.0
Net Weight:
Lbs.
®
Form No. BP7211-8

Advertisement

Table of Contents
loading

Summary of Contents for Emerson ODYSSEY CF2454WW02

  • Page 1 READ AND SAVE THESE INSTRUCTIONS Model No. CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02 26.0 Net Weight: Lbs. ® THE ODYSSEY Series Ceiling Fan Owner's Manual Part No. F40BP72110008 Form No. BP7211-8...
  • Page 2: Safety Instructions

    WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
  • Page 3: Tools Needed For Assembly

    This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. One six-inch blade screwdriver One stepladder 50-100 ft.
  • Page 4: Electrical Requirements

    Electrical Requirements SECTION A Assembly Instructions Your new ceiling fan will require a grounded electrical for Installing the CF2454 supply line of 120 volts AC, 60 Hz, 15 amp circuit. Ceiling Fan with a The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.
  • Page 5 9. Screw two 1-1/4” threaded studs (supplied) into 5. Using wiring connectors (supplied), connect the the motor (Figure 6). Leave approximately 7/8” of white, red, blue, brown, and yellow wires from the the stud extending above the motor. Slide the downrod to the white, red, blue, brown and yellow motor cover over the downrod and rotate the cover wires of the ceiling fan (Figure 4).
  • Page 6 LIGHT KIT WARNING CONNECTORS ADAPTER ASSEMBLY REVERSING SWITCH It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are proper- MOTOR SHAFT ly installed could result in the fan falling. 11.
  • Page 7 WARNING To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet FAN MOTOR AND HOUSING ASSEMBLY box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced.
  • Page 8 22. Connect the black wire from the wiring harness to SECTION B the black (hot) supply wire (Figure 4). Connect Assembly Instructions for the white wire from the wiring harness to the Installing the CF2454 Ceiling Fan white (neutral) supply wiring. Connect the green ground wires from the hanger bracket and the with Any Other Control Method hanger ball to the supply ground wire.
  • Page 9 NOTE: Make sure the red and brown leads are WARNING capped with wire connectors. Make sure red, brown, and yellow wire connectors are completely It is critical that the clevis pin in the motor coupling inside motor coupling cover and not pinched is properly installed and the setscrew securely tight- between the motor coupling cover and motor.
  • Page 10 14. Position the center styrofoam section on the 18. Secure the light kit plate assembly to the light kit upper section, and then position the fan motor adapter assembly by threading three 8-32 x 3/8” and housing on the center section so that the bot- phillips head screws (supplied) into the threaded tom of the motor is facing you (Figure 24).
  • Page 11 NOTE: CEILING COVER, WARNING SUPPLY WIRES AND OUTLET FAN WIRES OMITTED FOR CLARITY. The fan must be hung with at least 7' of clearance from floor to blades (Figure 30). CEILING HANGER BRACKET AT LEAST Figure 32 HANGER BALL/ DOWNROD ASSEMBLY WARNING FLOOR To avoid possible fire or shock, do not pinch wires...
  • Page 12: Final Assembly

    5. Obtain the die cast glass holders and light kit glass WARNING from the protective bag. 6. Position light kit glass carefully on a convenient Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire surface with the open side face down.
  • Page 13: Maintenance

    Maintenance LIGHT KIT KEYHOLE ADAPTER IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. BOTTOM VIEW When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. GLASS ASSEMBLY Abrasive cleaning agents are not required and should SCREW...
  • Page 14: Repair Parts

    Repair Parts...
  • Page 15: How To Order Repair Parts

    Repair Parts Listing Model No. Description CF2454BS02 CF2454WW02 CF2454BQ02 CF2454PW02 Bracket Assembly, Hanger 760732 760732 760732 760732 Hanger ball/downrod Assembly 761632-17 761632 761632-21 761632-23 Cover, Ceiling 761795-3 761795 761795-5 761795-6 Capacitor, Auxiliary 761453 761453 761453 761453 Cover, Motor Coupling 761621-15...
  • Page 16: Limited Warranty

    LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan.