Emerson CF244BS00 Owner's Manual

Emerson CF244BS00 Owner's Manual

44” & 52” damp & wet location ceiling fan
Hide thumbs Also See for CF244BS00:

Advertisement

BP7408-1 44" &
52" Curva
READ AND SAVE THESE INSTRUCTIONS
CURVA
44" & 52" Damp &
Wet Location Ceiling Fan
44" Model Numbers
for Damp Locations
CF244BS00
Brushed Steel
CF244CRM00
Chrome
44" Model Numbers
for Wet Locations
CF244WW00
Appliance White
CF244ORB00
Oil Rubbed Bronze
Net Weight:
Part No. F40BP74080001
8/31/10
3:50 PM
Owner's Manual
CF252CRM00
CF252ORB00
18.3
Lbs.
Page 1
52" Model Numbers
for Damp Locations
CF252BS00
Brushed Steel
Chrome
52" Model Numbers
for Wet Locations
CF252WW00
Appliance White
Oil Rubbed Bronze
19.2
Net Weight:
Form No. BP7408-1
UL Model No.: CF244 & CF252
Lbs.

Advertisement

Table of Contents
loading

Summary of Contents for Emerson CF244BS00

  • Page 1 CURVA ™ 44” & 52” Damp & Wet Location Ceiling Fan Owner's Manual 44” Model Numbers 52” Model Numbers for Damp Locations for Damp Locations CF244BS00 CF252BS00 Brushed Steel Brushed Steel CF244CRM00 CF252CRM00 Chrome Chrome 44” Model Numbers 52” Model Numbers...
  • Page 2: Safety Instructions

    WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
  • Page 3: Unpacking Instructions

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. UL Model No.: CF244 & CF252...
  • Page 4 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 4 A. FAN MOTOR F. LIGHT KIT B. CEILING COVER ASSEMBLY PLATE G. GLASS SHADE C. COUPLER COVER N. LOOSE PARTS BAG D. FAN BLADES (3) M. HANGER E. LOWER HOUSING BALL/DOWNROD ASSEMBLY L.
  • Page 5: Electrical Requirements

    Ceiling Fan Procedures KEY HOLE SLOT (2) General Your Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a receiver mounted inside the Figure 2 ceiling cover of the fan motor housing. This system allows you to regulate your ceiling fan speed and light intensity.
  • Page 6 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 6 6. Remove and retain the wire connectors 11. Carefully turn the partially assembled from the white and blue wires. ceiling fan right side up and place the securely into packing 7.
  • Page 7 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 7 16. Reinstall the hanger ball (Figure 8) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the DOWNROD DOWNROD...
  • Page 8: Your Ceiling Fan How To Hang

    BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 8 How to Hang WARNING Your Ceiling Fan Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse WARNING box before wiring.
  • Page 9: How To Wire Your Ceiling Fan

    BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 9 1. Position the receiver into the ceiling NOTE: CEILING COVER, SUPPL Y WIRES AND FAN cover as shown in Figure 12. Place the WIRES OMITTED FOR CLARITY. antenna wire on top of the receiver. OUTLET 2.
  • Page 10 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 10 OUTLET BOX BLACK SUPPLY WIRE HANGER BRACKET BLACK FAN WIRE HANGER BRACKET GROUND WIRE BLACK/WHITE RECEIVER WIRE (GREEN) BLUE FAN WIRE HANGER BALL BLUE RECEIVER GROUND WIRE WIRE (GREEN) OPEN PORTION OF RECEIVER SUPPLY GROUND...
  • Page 11: How To Assemble Your Light Kit Glass Shade

    BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 11 How to Assemble Your How to Assemble Your Light Kit Glass Shade No Light Cover Plate 1. Screw in two 50-watt (maximum) WARNING halogen mini candelabra base bulbs in the light kit plate sockets (Figure 15). Do not install any light bulbs into the light kit plate if using the cover plate.
  • Page 12: Remote Control Procedures

    A storage bracket is provided for holding your remote control when not in use. If you Your Emerson receiver is equipped with a desire to use the bracket, install it on a wall preset memory feature. If the AC supply to...
  • Page 13 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 13 Setting Operating Frequency of Remote Control Your remote control has code switches which must be set in one of 32 possible code combinations (Figure 18). The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position.
  • Page 14: Maintenance

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. UL Model No.: CF244 & CF252...
  • Page 15 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 15 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Ceiling Fan Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1.
  • Page 16 Wet Part Numbers Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No. No. Description CF244BS00 CF252BS00 CF244CRM00 CF252CRM00 CF244WW00 CF252WW00 CF244ORB00 CF252ORB00 Hanger Pack Consisting of: 761655-17 761655-17 761655-88 761655-88 761655-14 761655-14 761655-32...
  • Page 17: Repair Parts

    BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 17 Repair Parts 10 - 52" 11- 44" Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: •...
  • Page 18 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 18 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 19: Limited Warranty

    If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL...
  • Page 20 BP7408-1 44" & 52" Curva 8/31/10 3:50 PM Page 20 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74080001 Printed in China 08/10 Form No. BP7408-1 UL Model No.: CF244 & CF252...

Table of Contents